IM Injection Criteria | Inter-rater Reliability | Evaluator | |||||
---|---|---|---|---|---|---|---|
H1 | H2 | RT | AI1 | AI2 | |||
α | κ | M(Sd) | M(Sd) | M(Sd) | M(Sd) | M(Sd) | |
Introduced themselves and explained the procedure to the patient. | 0.001 | 0.196 | 1.86 (0.5) | 1.88 (0.4) | 1.91 (0.4) | 2 (0.0) | 1.95 (0.3) |
Checked the accuracy and suitability of the medication and verified it was the correct patient (verbal confirmation is sufficient). | 0.117 | 0.269 | 1.30 (0.9) | 1.51 (0.9) | 1.26 (0.9) | 1.95 (0.2) | 1.91 (0.4) |
Ensured patient privacy (verbal confirmation is sufficient). | 0.437 | 0.076 | 0.47 (0.9) | 0.60 (0.8) | 0.79 (0.9) | 1.91 (0.3) | 1.86 (0.5) |
Syringe Preparation (Checked the expiration date of the syringe and ensured the packaging was intact), stated that they prepared the medication by drawing it into the syringe. | 0.125 | 0.054 | 1.05 (0.4) | 1.12 (0.9) | 1.21 (0.5) | 1.63 (0.5) | 1.56 (0.6) |
Indicated the injection site visually (upper outer quadrant). | 0.043 | 0.072 | 1.70 (0.6) | 1.81 (0.5) | 1.84 (0.5) | 1.98 (0.2) | 1.95 (0.2) |
Cleaned the injection area with an antiseptic cotton swab, wiping outward in a circular motion from the center, covering a radius of approximately 5 cm.* | 0.049 | -0.007 | 1.81 (0.4) | 1.98 (0.2) | 1.91 (0.3) | 2 (0.0) | 1.67 (0.7) |
Placed a dry cotton swab between the 4th and 5th fingers of the assisting hand. | 0.002 | 0.065 | 1.77 (0.6) | 1.79 (0.6) | 1.88 (0.3) | 1.88 (0.3) | 1.72 (0.5) |
Stretched the skin at the injection site using the thumb and index finger of the assisting hand. | -0.005 | 0.177 | 1.77 (0.7) | 1.79 (0.6) | 1.84 (0.5) | 1.86 (0.4) | 1.98 (0.2) |
Held the syringe with the active hand as if holding a pen. | 0.001 | 0.289 | 1.88 (0.5) | 1.93 (0.3) | 1.88 (0.4) | 2 (0.0) | 1.98 (0.2) |
Inserted the needle perpendicular to the skin. | -0.007 | 0.071 | 1.91 (0.4) | 1.93 (0.3) | 1.91 (0.4) | 1.98 (0.2) | 1.88 (0.3) |
Pulled back the syringe plunger slightly with the assisting hand to check for blood. | -0.005 | 0.077 | 1.81 (0.5) | 1.84 (0.4) | 1.95 (0.2) | 1.86 (0.4) | 1.72 (0.7) |
Injected the medication into the muscle by pressing the syringe plunger with the assisting hand (no actual medication will be injected into the model) | 0.033 | 0.184 | 1.74 (0.5) | 1.77 (0.5) | 1.88 (0.3) | 2 (0.0) | 1.65 (0.8) |
Removed the needle at the same angle and speed as insertion while applying light pressure to the injection site with a cotton swab using the assisting hand. | 0.005 | 0.030 | 1.98 (0.2) | 1.98 (0.2) | 1.95 (0.2) | 2 (0.0) | 1.88 (0.4) |
Disposed of the syringe and other waste materials in appropriate disposal containers (without recapping the needle). | 0.058 | 0.056 | 1.60 (0.7) | 1.86 (0.4) | 1.91 (0.4) | 1.98 (0.2) | 1.72 (0.6) |
Informed the patient that the procedure was complete and/or said, “Get well soon.” | 0.044 | 0.330 | 1.67 (0.8) | 1.77 (0.6) | 1.74 (0.7) | 2 (0.0) | 2 (0.0) |